Lead-acid
Estimated minimum nominal capacity (50% usable)
—
Estimate session consumption and nominal battery capacity from radio current and operating time.
Estimated minimum nominal capacity (50% usable)
—Estimated minimum nominal capacity (90% usable)
—Combine the radio's receive and transmit current, taking into account how long it spends in each state and the selected TX factor.
Multiply the average consumption by the operating hours to estimate the session's total consumption, expressed in Ah.
Adjust the total consumption using the assumed usable capacity: 50% for lead-acid and 90% for LiFePO4.
These percentages are planning assumptions, not universal limits.